Calibration Verification Kit
Core Temperature With Striking Speed and Accuracy
Target the temperature of your patients with the fastest,safest,most accurate thermometric system in veterinary medicine. In just five seconds, the OTOTEMP[TM] VETERINARY Tympanic Temperature Scanner measures core temperature in animals of all sizes- from parakeets to elephants-providing the quickest diagnostic indication...with the kindest of noninvasive probes. The OTOTEMP VETERINARY is so easy to use you'll find it indispensible in the clinic. Simply insert the people into the animal's ear canal and scan for the tympanic membrane. The patented infrared scanner take fifty readings in five seconds, locking onto the highest temperature.Fast,Accurate,and Noninvasive, the OTOTEMP VETERINARY is well accepted by patients... and well appreciated by their owners too. Core Temperature in 5 seconds Sale and easy to use Well accepted by patients
What is the OTOTEMP VETERINARY Infrarred Tympanic Temperature Scanner?
The only noninvasive real-time thermometer via the tympanic membrane without the need for corrections. The fastest and most cost-effective of any temperature method, the OTOTEMP VETERINARY can be used on both mammals and birds.
How Does Tympanic Compare to Rectal Temperature?
  1. Rectal and tympanic tenperatures track closely on quiescent patients.

  2. Rectal temperature will lag behind tympanic temperature in the presence of thermal dynamics. For instance on an anesthetized patient the rectal temperature can lag behind by several degrees for as long as an hour. By knowing the real-time core temperature,it is possible to immediately recognize the earliest signs of hypothermia.

    Recently,a tiny Pomeranian underwent a surgical procedure for removal of deciduos teeth.Both tympanic and rectal temperatures prior to anesthesia were 102.5F. The attending veterinarian, shortly after anesthetizing the patient,observed signs of distress and took a second tympanic temperature. This time the OTOTEMP VETERINARY read 87F,confirming the distree, Warming was instituted immediately and the Pom survived. The rectal temperature monitor never indicated the temperature drop.

  3. Tympanic temperature is not subject to the many artifacts of rectal temperature such as exercise, hypovolemia, placement etc.For example a hyperactivedog, bounding around the waiting room could have an erroneously high rectal temperature due to the metabolic heat generated by rectal-area muscles

    During the swimmer a cheetah escaped from its housing at a large zoo.After running the perimeter of the grounds for over an hour in 95 F heat, it was caught and brought to the infirmary. The rectal temperature was 112 F Standard protocol dictated that the animal be entharized because of the certainty of brain damage. However, when the animal's tympanic temperature was taken with the OTOTEMP VETERINARY, it wasnormothermic at 102 F. The medical director accepted the tympanic reading and the animal was spared.To date the animal is healthy, with no evidence of brain or other organ damage.

  4. Rectal temperature is not without risk of injury both to the animal and to the veterinarian. Tympanic measurement eliminates this risk.

  5. Rectal temperature measurement,even with electronic thermometers is time-consuming and unpleasant. Tympanic temperature measurement is quick, easy, and pleasant for all involved.
Do Other Infrared "Tympanic" Thermometers Work with Animals?
NO These Instruments, correctly called ear thermometers are used with human patients primarily as screening devices. They measure the temperature of the the cooler skin of the outer ear canal and add a correction factor to make up for the temperature deficiency.These correction factors are simply not valid for animals. The OTOTEMP VETERINARY has no correction factors because none are required when measuring true tympanic temperature.
To request technical and clinical data, please call Exergen Corporation . Patent Nos. 4,993,419 and 501813. Others pending.
Non-contact IR
temperature
sensors.
Read more
Temporal Artery
Thermometers
and Accessories.
Read more
Retail Cunsumer
Information
Center
Read more
Product Specifications
  • Direct tympanic temperature measurement without correction
  • Temperature range: 65F(18C) to 130F(54C)
  • Ambient temperature range: 32F(0 to 110F) (43C)
  • Clinical accuracy: +-0.2F( 0.1C)
  • Unique scanning feature takes 50 reading per scan locking peak value
  • Durable, industrial-grade case, cover by protective copper shielding
  • 9-vatt battery power: approximately 5000 reading per battery
  • Converts easily to Fahrenheit or Cels
  • Instrument and covers are gassterilizable
  • Cost-efficient disposable probe cover 
Exergen Corporation manufactures an Extensive line of proprietary infrared scanner thermometers, and controls used in a wide variety of medical and industrial application and is the world leader in portable thernal infrared instrumentation . The company is committed to scientific inq In order to develop improved methods of thermometry for patient care.