#93 In-line Pre-Calibrated Transmitter for Easy, Reliable
Installation
Model t/c.XMTR- * - ** 4-20
mA Transmitter
Current loop transmitters for
thermocouples have traditionally
been designed as "hockey pucks" in order
to fit thermowell heads, thus complicating installation
for applications not using a thermowell,
and requiring a housing for protection. Additionally, they
generally have to be calibrated
to a specific range, usually with thermo- couple
simulators or other such device, thus requiring
significant set up time and the possibility of unauthorized
recalibration.
The t/c.XMTR is designed to
overcome both of the costly
inconveniences:
- In-line design is only slightly
larger than the cable and
requires no mechanical support.
- Precalibrated for thermocouple
type and temperature range
eliminates all adjustments,
requirements for simulators,
etc.
- Hermetically sealed stainless
steel construction is suitable
for the harshest service without any additional
packaging.
The t/c.XMTR is specifically
designed to interface to any
model IRt/c (or any conventional thermocouple) by
a simple thermocouple connector or splice. The 2-wire
current loop can be used in any conventional current
loop circuit that is scaled for the temperature range
of interest.
Model Selection
- Select the correct IRt/c model for
the application: target
temperature, target material,
field-of-view.
- Select the t/c.XMTR model for the
t/c type and temperature range
from the table below. Example:
t/c.XMTR-K150
Installation
- Install IRt/c as normal.
- Connect IRt/c output cable to
the thermocouple input side of the
transmitter using standard t/c
connector, splice, or other standard
method of connecting thermocouple
cables. Transmitter should be located in a an environment no
higher than 158°F (70°C) in
temperature. Additional t/c
extension wire may be added as required.
Use of twisted shielded t/c wire is recommended
(same as on the IRt/c and transmitter),
and maintain shield connections.
- Check load on transmitter and
power supply voltage for
correct range (10 VDC minimum @ 10W;
to 22 VDC minimum @ 1KW). 4.
Set readout device (controller, computer, PLC, etc.)
for 4 to 20 mA range to match the t/c.XMTR model
range.
- Set readout device (controller,
computer, PLC, etc.) for 4 to 20 mA range to match the t/c.XMTR
model range.
- Perform final calibration of IRt/c
installation in accordance with
IRt/c instructions, using offset on
current loop readout device.
- Installation complete.


Model Numbers
Example: t/c.XMTR-J-150 |
J150
K150 |
J500
K500 |
J1200
K1200 |
K2000 |
S3000 |
| Temperature at 4 mA |
32 °F |
| Temperature at 20 Ma |
150°F
(65°C) |
500°F
(260°C) |
1000°F
(540°C) |
2000°F
(1100°C) |
3000°F (1650°C) |
|