| Sensing Range |
-50 to 550 °F (-45 to
290 °C) |
| Ambient Temperature
Range |
0 to 160 °F (-18 to
70 °C) |
| Optimum Range
Selections |
Eight models per t/c
type (see Temperature Selection Guide) |
| Field-of-View |
1:1 (60°)
approximately |
| Minimum Spot Size |
0.3" (8 mm) |
| Spectral Response |
6.5 to 14 µ |
| Output Impedance |
3 Kohms approximately |
| Cable |
Thermocouple extension
grade, PVC jacket, unshielded |
| Dimensions |
1.28" x .71"
Diameter (32.5 x 20 mm) |
| Weight |
1.4 oz (40 g) with
cable |
| Housing |
High strength ABS,
hermetically sealed, exceeds NEMA 4, 4x; IP65, 67,
intrinsically safe. Two locknuts supplied. |
Back to
IRt/c Specifications
|