| Sensing Range |
-50 to 1200 °F (-45 to 650 °C) |
| Optimum Range Selections |
Eight models per t/c type (see Temperature Selection Guide) |
| Field-of-View |
10:1 (6°) approximately |
| Minimum Spot Size |
0.8" (20 mm) |
| Spectral Response |
6.5 to 14 µ |
| Output Impedance |
4 to 8 Kohms approximately |
| Cable |
Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service. |
| Dimensions |
3.76" x 1.375" Diameter (96 x 35 mm) |
| Weight |
6.5 oz (184 g) with cable |
| Housing |
Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal. |
| Air Purge |
Built-in; cooling capacity to 400 °F (200 °C) ambient; 3; (0.9 m) polyurethane tubing provided |