| Sensing Range |
-50 to 550 °F (-45 to 290 °C) |
| Ambient Temperature Range |
0 to 160 °F (-18 to 70 °C) |
| Optimum Range Selections |
Eight models per t/c type (see Temperature Selection Guide) |
| Field-of-View |
3:1 (17°) approximately |
| Minimum Spot Size |
0.25" (6 mm) |
| Spectral Response |
6.5 to 14 µ |
| Output Impedance |
4 to 8 Kohms approximately |
| Cable |
Thermocouple extension grade, PVC jacket, unshielded |
| Dimensions |
1.28" x .71" Diameter (32.5 x 20 mm) |
| Weight |
1.4 oz (40 g) with cable |
| Housing |
High strength ABS, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe. Two locknuts supplied. |